- 6 minutes to read

Add or manage Log View

In this guide, you will learn how to add and manage Log Views to provide your business with a way to find business transactions using the Nodinite end-to-end Logging feature. Your business gets self-service using the Nodinite Log Views and can easily search for business transactions spanning all your systems integrations solutions.

graph LR roUser(fal:fa-users-class End-Users) roLV(fal:fa-hdd Log View) roAdmin(fal:fa-user-cog Nodinite Administrator) roNE[fal:fa-alarm-clock Non-Events Monitoring] roUser --> |Search for business transactions| roLV roAdmin --> |Manage/Edit| roLV roLV -.-> |Enables| roNE
# Topic
1. Features
2. Manage Log View
2.1 Add new Log View
2.2 Manage existing Log View
3. General tab
4. Search setup tab
5. Data to search tab
6. Display result tab

1. Features

The Nodinite Log View is a composite view where filters and settings regulate what options are available to end-users being part of one or more Roles.

There are maný filter options to choose between, and you can create virtually any type of Log View to facilitate search operations for end-users.

TIP: Use the Log Views to enable Non-Events monitoring.

Below is the list of filter options:

2. Manage Log View

2.1 Add new Log View

As the Nodinite Administrator, click on the Add Log View button from the Log Views Overview.

Add Log View
Click on the Add Log View button to create a new Log View.

2.2 Manage existing Log View

As the Nodinite Administrator, from the Log Views Overview; You can manage existing Log Views by clicking on one of the entries.

3. General tab

From the General tab, the Nodinite administrator sets essential and required information for the Log View.

  • Name - Mandatory field - A unique name is required to create a new Log View.
  • Description - Optional field - A short user-friendly description about the Log View.
  • Website - Optional field - Use the link field feature to allow the end-user to click and navigate to the specified address.
  • Roles - Required setting - Grant and access rights.

Name, Description, and Website
Example of the essential and required information for a Log View.

3.1 Roles

To manage the set of Roles with access to the Log View, click on the Edit button in the Roles section.

Edit Roles
Edit the set of Roles to manage the grants set on the Log View

Then, grant a selection of Roles to access the Log View.

Next, click on the Selected tab and manage the permissions for the Roles.
Manage permissions
Manage the permission set for Roles

  • Access this View - Allow or deny user access to this Log View.
  • View Body - Allow or deny user the ability to view and download er the ability to view the payload using a Stylesheet
  • Resend - Allow or deny user the ability to resend messages.

The Nodinite Log Events can include options to resend messages to a pre-defined target. Please review the Context Options user guide for details.
The System Parameter AllowResubmit must be set to 'true' to allow the resend feature.

  • Repair - Allow or deny user the ability to repair messages.

The System Parameter AllowResubmit must be set to 'true', to allow the repair feature. Likewise, the System Parameter AllowRepair must also be set to 'true', to allow the repair feature.

For additional details, please review the Permission Set for Log Views user guide.

4. Search setup tab

In the Search Setup tab, the Nodinite Administrator manages the search options based on Search Fields and other pre-defined properties of a Nodinite Log Event.

Search setup tab
Example of options in the Search Setup tab.

4.1 Time Interval Configuration

You can add a Time Interval Configuration to the Log View to regulate the available period to search by for the end-user.

Time Interval Configuration
Select the Time Interval Configuration to use with the Log View

4.2 Restrictions

The Nodinite Administrator can define restrictions to regulate exactly what content can be presented to the end-user.

These restrictions are not visible for the end-user, and there is no way for the to circumvent these.

4.3 Search setup

To facilitate search operations and narrow down the search options for end-users, the Nodinite Administrator can define what Search Fields are available. In addition, pre-set the proper relational operators and default values to make the search even easier and faster to use.

4.4 Other

When checked, the search operation runs immediately with the default values.

4.4.2 Search by Log Status Code

Log Status Code is a number that tells us if the processing of the message went fine.

For example, in BizTalk, the status code for OK is 0

4.4.3 Search by Sequence Number

Sequence Number is a number labeled on the message or event.

You can allow search by Sequence Number, which is helpful when you know exactly what Log Event to get.

4.4.4 Search by Log text

Log text is a piece of information coming with the message or event.

You can allow search by Log text, which is helpful to narrow down the result set.

5. Data to search tab

From the Data to Search tab, you can further refine the filters in use for the Log View.
Data to Search tab
Additional filter options from within the Data to Search tab.

6. Display result tab

From the Display result tab, the Nodinite Administrator can add one or more Group by fields and adjust the columns in the result from a search operation.

Display Result tab
Example with the display result options

6.1 Group by options

  • Grouping - Group the result by the selected Field.

You can select a maximum of four group by fields.

  • Lock group by - When checked, prevent the user from changing the group by field(s).
  • Use paging for events in group - When checked, there is an improvement in performance for a large number of groups and/or a large number of events in each group.
  • Display a group summary - When checked, display a summary row for each group.
  • Collapse the group - When checked, collapse the list of events for each group.

6.2 Column Configuration

The Nodinite Administrator can fine-tune what columns are part of the search result. To rename the columns, use the Artifact Renaming feature!

Column Configuration
Custom Column configuration with Artifact Renaming

You can use three different methods for the columns selection:

  1. Default
  2. Manual Configuration
  3. Use an existing configuration, please review the Display Field Configurations user guide for details.

Next Step

Add or manage User
Add or manage Role

Nodinite Log Events
Roles
Users
Access Management